There was an error - please try again.
Thank you for your interest. We will return!

Contact us by filling out the form below

R856598 Stranded loose tube, single shea

sch-product-heading-ean 5703472632773
sch-product-heading-type R856598
Supplier Reichle & De-Massari AG
sch-product-heading-productno 79.84.012.515
sch-product-heading-provideproduct sch-product-provide-article-s
sch-product-heading-instock Out of stock79.84.012.515
Arrival time (days) 21
sch-product-heading-sales-packaging-size 1
sch-product-heading-minimumsale 1,000
sch-product-heading-unit M
Stranded loose tube, single sheathed cable, RP-rodent protected, universal-use, UV.FRLSZH sheath - green, Eca, 12 x 24f = 288 fibers G657A1

Environmental Characteristics
Temperature cycling -40 °C +70 °C / -40 °F +158 °F
Temperature cycling acceptance criteria ?a = 0,05 dB
Temperature cycling test method IEC 60794-1-22:F1
Operation temperature -40 °C to +70 °C / -40 °F to +158 °F
Storage / Transport temperature -40 °C to +70 °C / -40 °F to +158 °F
Thermal load 4.0900000000 MJ/m
Flammability vertical cable bundle Pass
Flammability vertical cable bundle test method EN 60332-3-22 (cat. A)
Smoke density Pass
Smoke density test method EN 61034-1, EN 61034-2
Halogen free, acid gases Pass
Halogen free, acid gases test method EN 60754-2
Mechanical Data
In-service tensile strength 1000 N
In-service tensile strength acceptance criteria ?a = 0,05 dB
In-service tensile strength test method IEC 60794-1-21:E1
Installation tensile strength 3000 N
Installation tensile strength acceptance criteria ?a = 0,05 dB after test
Installation tensile strength test method IEC 60794-1-21:E1
Crush resistance long term 1000 N/100mm
Long-term crush resistance acceptance criteria ?a = 0,05 dB prior release, no damage
Long-term crush resistance test method IEC 60794-1-21:E3A
Short-term crush resistance 2000 N/100mm
Short-term crush resistance acceptance criteria ?a = 0,05 dB after release, no damage
Short-term crush resistance test method IEC 60794-1-21:E3A
Impact resistance 10 Nm, 3 impacts, d=20 mm, R=300 mm
Impact resistance acceptance criteria ?a = 0,05 dB after test, no damage
Impact resistance test method IEC 60794-1-21:E4
Torsion L = 1 m, rotation angle ±180°, 10 cycles
Torsion acceptance criteria no damage
Torsion test method IEC 60794-1-21:E7
Repeated bending R=20 x cable diameter, 25 cycles
Repeated bending acceptance criteria no damage
Repeated bending test method IEC 60794-1-21:E6
Cable bend d=20 x cable diameter, 4 turns, 3 cycles
Cable bend acceptance criteria ?a = 0,05 dB after test, no damage
Cable bend test method IEC 60794-1-21:E11A
Minimum bend radius in service 215 mm
Minimum bend radius during installation 285 mm
Technical Data
Cable family code UX3x2,3EF
Cable type Stranded loose tube cable
Cable version n.a.
Cable application universal use
DoP number D9077
Fiber type G.657.A1
Fiber count 288
Fiber color coding 1.-12.: red, green, blue, yellow, white, grey, brown, violet, turquoise, black, orange, pink13.-24.: red, green, blue, yellow, white, grey, brown, violet, turquoise, natural, orange, pink(ring-marked)
Fiber count per tube 24
Loose tube count 12
Loose tube diameter 2,3 mm
FRP/coat. CSM nominal thickness [mm] 2.8 / 6.7
Armor Rodent protection
Outer sheath thickness 1,2 mm
Outer sheath material UV stable FRLSZH
Outer sheath color green
Sheath marking Ink-Jet, black
Cable outer diameter 14,2 mm
DIN / VDE 0888 code U-DQ(ZN)H wbg nx2,3
Expected lifetime min. 30 years
CPR classification Eca